OPERATE BYPASS
Ring
HOME
Tip Ring
TELCO
Tip
SYSTEM
4 3 2 1
C
C
C
C
Resident
Telco
Tip
Ring
Tip
Ring
8
9
BYPASS
Ring
TELCO
Tip
Bypass Board for Unit 1 Bypass Board for Unit 2
Ring
Ring
Ring
Tip Tip
Tip
Ring
Tip
Use 18-24 AWG
2 twisted pair
Important: You must program the Unit ID's for
each
EL25 wired in the series. See
“Multiple
Unit Set-Up”
page 19.
Important: The Voltmeter
measurement between the Tip
and Ring should read between
48 and 53 VDC.
When the EL25 units are
in use
, the bypass switches must be set to the
operate
position.
When the EL25 units are
disconnected
, the bypass switches must be set to the
bypass
position.
Wiring Multiple EL25 Units to Telco Line
Wiring Multiple EL25 Units
Up to 7 EL25s can share the same phone line. The bypass boards allow the EL25 units to be
disconnected without interrupting normal telephone operation.
Wiring Multiple EL25 Units
OPERATE BYPASS
Ring
HOME
Tip Ring
TELCO
Tip
SYSTEM
4
3
2
1
Last Bypass Board
4
3
2
1
Home Phone
Unit ID 2
Output Board
(See page 2)
Unit ID 1
Output Board
(See page 2)
Telco Entrance Box
Demarcation Point
Do Not overload the removable
terminal block connectors. One
wire per hole.
Important: The Bypass
Boards (located inside
the property)allow
access to the phone in
case
any
of the EL25s
fail.
Never
run
Data wires
and
High Voltage wires
in the
same
conduit. The high
voltage wires may interfere
with the data wires, possibly
causing the system to
malfunction.