Grounding the EL25
Grounding the EL25
Grounding the EL25
Ensure that the system is grounded properly.
The EL25 contains a number of static sensitive
components that can be
damaged
by static discharge.
O
f
f
O
f
f
On
On
On
Off
O
f
f
O
f
f
On
Off
Off
Other Ground Sources
within 12 ft of Unit
Ground to
Metallic Cold
Water Pipe
Ground to
Existing
Electrical
System
Green Ground
Wire
Earth Ground Rod
Electrical
Panel
Important: An Earth Ground Rod is
Strongly
Recommended
and should be no further than
12 ft from the unit and use a minimum of 12
gauge wire in most cases. The type and length
of earth ground rods vary by region.
Contact
the building inspector’s office in the
municipality where you plan to install the
unit for correct grounding materials and
installation procedures.
Before digging, contact local
underground utility locating
companies.
Avoid damaging gas, power,
or other underground utility
lines.
Do Not ground the EL25 to a
pedestal post (gooseneck) if
one is used.
12 ft Maximum
12 AGW Minimum